Why windowing matters. CT stores density in Hounsfield units (air −1000, water 0, brain about 35, fresh blood 60–80, bone several hundred and above). A screen shows about 256 grey levels, so a window chooses which slice of that range is spread from black to white. Reading every head CT in at least a brain, a subdural (W 200 / L 80) and a bone window avoids the classic misses: a thin subdural haematoma against the skull, and a non-displaced fracture.
Kernels are not windows. The kernel is chosen when the images are reconstructed from the raw data; the window is chosen when you look at them. A bone kernel cannot be recreated by windowing a soft-tissue series.
Why no 3D here? This scan was acquired step-and-shoot, so the slice spacing jumps where the blocks join. The viewer therefore treats it as a stack, not a volume. For multiplanar and 3D reconstruction see the next case, a helical scan with even 1 mm spacing.